ROUTE-MASTER Segment and Entity Calculator Tool Now AvailableROUTE-MASTER, the industry’s most capable Intrinsically-Safe Fieldbus Solution, now has a free and easy to use segment calculator design tool. The calculator allows you to design and document IS Fieldbus segments that include FISCO or Entity devices. Included in the tool is an intuitive Entity calculator that automatically checks your IS segments for hazardous area compliance. Go to E-HELP EXPRESS to request your FREE copy.
Get Data Sheet TRUNKSAFE.pdf (1.3M ) TRUNKSAFE in an Eggshell (590K ) * Patents Pending
TRUNKSAFE TS SeriesFault-Tolerant Fieldbus System The TRUNKSAFE Fault-Tolerant Fieldbus System provides a cost-effective, yet highly reliable, strategy to maintain continuous communications between field devices and a Distributed Control System in the event of any single point failure (such as an open- or short-circuit) on a FOUNDATION fieldbus™ H1 or PROFIBUS PA segment.
The First Redundant Fieldbus Physical Layer TRUNKSAFE consists of a Host Interface Kit (Redundant) device coupler (6- or 12-Way). Failure in either path results in auto-termination in the device coupler and continued communications on the segment.
DIN-Rail and Complete Field-Mount Packages TRUNKSAFE Device Couplers and Power Conditioners snap onto standard DIN-rail. To reduce specification and installation time, device couplers can also be ordered in a variety of our ready-to-install field-mount, weather-proof enclosures complete with cable glands.
Get Data Sheet for Systems with Power Supply rm100.pdf (707K )
Get Data Sheet for RM110 rm110.pdf (281K )
Connect Directly to FISCO or Entity Devices The ATEX-approved version Device Couplers (RMA100C) can be installed in IIB or IIC areas connecting FISCO or Entity devices from Zone 0, 1 and 2.
Intrinsically-Safe, Isolated Power Supply The ROUTE-MASTER's rack-mounted fieldbus power supply delivers redundant intrinsically safe segment power for up to eight fieldbus segments. The isolated segments requires no ground and have two trunks available with 350ma each. Passive conditioning and redundant DC Power ensure an exceptionally reliable fieldbus segment.
Industry-First Advantages Available in 4-, 8-, 10- and 20-spur models, ROUTE-MASTER Fieldbus Device Couplers use the same technology as our industry-first TRUNKGUARD Fieldbus Device Couplers to provide fully automatic segment termination. The patented technology prevents fieldbus segment failure from under- or over-termination, a major problem in fieldbus startups. The ROUTE-MASTER's auto-termination feature assures that local parts of a fieldbus segment will continue to function if remote parts of that segment are accidentally disconnected. This prevents costly downtime and hazardous situations. Other unique features include diagnostic LEDs that positively indicate power status on each spur, spur short circuits, status of auto-termination, as well as convenient connections for a fieldbus hand-held configurator.
Short Circuit Protection On detection of excess current on a spur, the ROUTE-MASTER reacts immediately to switch spur current to a nominal trickle-level, rather than limiting the fault current to a fixed (and always higher) level as is typically done by competing units. With removal of the short, the spur is automatically reconnected to the segment.
HAZARDOUS AREA MOUNTING ROUTE-MASTER System Design allows live working on Trunk and Field. Although ROUTE-MASTER device couplers are DIN rail mounted, they typically are supplied in Aluminium, GRP or SS Enclosures complete with glands and suitable for the area classification. The IS design of the system allows live working on the trunk and spurs for most installations. Because of the spur rating of Zone 0, Ex ia, FISCO or Entity devices can be directly connected from any zone or gas group without additional barriers.
Get Data Sheet tg200.pdf (650K )
General Purpose and Hazardous Area Installations For installation in General Purpose and Non-Incendive (Class 1, Division 2) areas, TRUNKGUARD Fieldbus Device Couplers can be matched with our FPS200 Fieldbus Power Supplies. For intrinsically-safe applications, see the RM100 Intrinsically-Safe Fieldbus System. For installation in Zone 1 areas, see the TG300 Series Fieldbus Device Coupler.
Industry-First Advantages Available in 4-, 8-, 10-, 12- and 20-spur models, TRUNKGUARD is the first fieldbus Device Coupler to provide end of line sensing auto segment termination. The patented technology prevents fieldbus segment failure from under- or over-termination, a major problem in fieldbus startups. The TRUNKGUARD's auto-termination feature assures that local parts of a fieldbus segment will continue with proper termination even if remote parts of that segment are accidentally disconnected. This prevents costly downtime and hazardous situations. Other unique features include diagnostic LEDs that positively indicate power status on each fieldbus spur, spur short circuits, status of auto-termination, as well as convenient connections for a fieldbus hand-held configurator.
Short Circuit Protection On detection of excess current on a fieldbus spur, the TG200 reacts immediately (20 microseconds) to switch spur current to a nominal trickle-level, rather than limiting the fault current to a fixed (and always higher) level as is typically done by competing units. With removal of the short, the spur is automatically reconnected to the fieldbus segment.
DIN-Rail and Complete Field-Mount Packages TRUNKGUARD Fieldbus Device Couplers snap onto standard DIN-rail. To reduce specification and installation time, they can also be ordered in a variety of our ready-to-install field-mount, weather-proof enclosures complete with cable glands. Options include GRP (Glass Reinforced Polyester) and stainless steel enclosures with glands for armored or unarmored cable.
Get Data Sheet tg300.pdf (424K )
Designed for Zone 1 Areas The TRUNKGUARD 300 Series Fieldbus Device Coupler is designed and approved for use in Zone 1 and Zone 2 with flameproof Exd devices. Each device coupler channel can be manually de-energized using a key-operated magnetic interlock. This allows individual fieldbus devices to be maintained without de-powering the entire segment even in Zone 1 areas. The fieldbus device coupler's LED indicators show the current state of each channel (NORMAL, FAULT or DE-ENERGIZED).
Industry-First Advantages Available in a 4- or 8-spur configuration, the TRUNKGUARD 300 Series is the first to provide end of line sensing auto segment termination. The patented technology prevents fieldbus segment failure from under- or over-termination, a major problem in fieldbus startups. The TRUNKGUARD's auto-termination feature assures that local parts of a fieldbus segment will continue to function if remote parts of that segment are accidentally disconnected. This prevents costly downtime and hazardous situations. Other unique features include diagnostic LEDs that positively indicate power status on each fieldbus spur, spur short circuits, status of auto-termination, as well as convenient connections for a fieldbus hand-held configurator.
Short Circuit Protection On detection of excess current on a spur, the TG300 reacts immediately to switch spur current to a nominal trickle-level, rather than limiting the fault current to a fixed (and always higher) level as is typically done by competing units. With removal of the short, the spur is automatically reconnected to the fieldbus segment.
Easy Hazardous Area Installation Housed in simple Ex e enclosures, safety approvals allow installation in Zone 1 and 2 locations with high power and Exd devices.
Get Data Sheet tps400.pdf (1.1M )
The TPS400 TRUNKGUARD Fieldbus Power Supply provides isolated, conditioned power to up to four FOUNDATION fieldbus™ segments. Designed for flexibility and ease of implementation, the TPS400 is fully compliant with FF831-1 (the technical specification for fieldbus power supplies). It is designed for use with MooreHawke Series 200 and Series 300 TRUNKGUARD Fieldbus Device Couplers, as well as any other manufacturer’s non-intrinsically-safe fieldbus device couplers. The DIN-style rail-mount TPS400 provides 350mA or 500mA to up to four segments.
Complete Device Coupler Compatibility for General and Hazardous Area Installations For use with the TPS400 Fieldbus Power Supply, MooreHawke offers Fieldbus Device Couplers for installation in General Purpose, Zone 2/Division 2 locations (TRUNKGUARD Model TG200) and Zone 1 locations (TRUNKGUARD Model TG300).