Moore Industries: The Interface Solution Experts MooreHawke: Fieldbus Interface Solutions
Fieldbus Device Couplers and Power Supplies
Fieldbus Device Couplers and Power Supplies
E-Help Express: Click Here First
Main Product Selection Index
Data Sheet Library
Installation Manual Library
Certifications & Safety-Related Instrumentation
Problem Solvers Application Notes
Add me to Email Technology Update List
Site Map
Chinese Web Site
Fieldbus Device Couplers and Power Supplies

Fieldbus Device Couplers and Power Supplies

Deliver a fast and easy way to connect, protect, power and terminate multiple fieldbus devices in FOUNDATION fieldbus™ and PROFIBUS PA segments.


Get Your Copy of
our NEW white paper
"Introduction to Fieldbus"

(503K)
Click Here
to view the
MooreHawke
Overview!

(1.1M)

Detailed product data sheets are available in PDF format by clicking on the product names below. PDF files require Adobe Reader, which can be downloaded free from Adobe's Web site.
Featured Fieldbus Solutions
Model Description
TS Series TRUNKSAFE™ Fault-Tolerant Fieldbus System

Trunkguard

Get Data Sheet
TRUNKSAFE.pdf (760K )

TRUNKSAFE in an Eggshell (590K )

* Patents Pending


TRUNKSAFE TS Series
Fault-Tolerant Fieldbus System

The TRUNKSAFE Fault-Tolerant Fieldbus System provides a cost-effective, yet highly reliable, strategy to maintain continuous communications between field devices and a Distributed Control System in the event of any single point failure (such as an open- or short-circuit) on a FOUNDATION fieldbus™ H1 or PROFIBUS PA segment.

The First Redundant Fieldbus Physical Layer
TRUNKSAFE is comprised of two redundant fieldbus DC power conditioners and specially-engineered device coupler (6- and 12-spur models) that, in combination, provide a secure, and redundant, fieldbus physical layer.

  • Implement a redundant, yet cost-effective, fieldbus physical layer for important and plant-critical segments.
  • Maintain all process and diagnostic communications without interruption, even if the network cable is broken or shorted.
  • Compatible with FOUNDATION fieldbus H1 and PROFIBUS PA networks and devices without hardware or software changes.
  • Advanced physical layer diagnostics monitor and report open- and short-circuits, DC power status and segment noise.
  • Electronic and fully auto-resetting spur short-circuit protection that prevents segment failure caused by single device faults.

DIN-Rail and Complete Field-Mount Packages
TRUNKSAFE Device Couplers and Power Conditioners snap onto standard DIN-rail. To reduce specification and installation time, device couplers can also be ordered in a variety of our ready-to-install field-mount, weather-proof enclosures complete with cable glands.

TG200 TRUNKGUARD™ Series 200 FOUNDATION Fieldbus™/PROFIBUS PA Device Coupler
(For General Purpose and Non-Incendive Installations)

Trunkguard

Get Data Sheet
tg200.pdf (674K )


TRUNKGUARD Series 200 Fieldbus Device Couplers (TG200) deliver a fast and easy way to connect multiple fieldbus devices to a main fieldbus trunk in FOUNDATION fieldbus™ (H1) and PROFIBUS PA networks.

General Purpose and Hazardous Area Installations
For installation in General Purpose and Non-Incendive (Class 1, Division 2) areas, TRUNKGUARD Fieldbus Device Couplers can be matched with our FPS200 Fieldbus Power Supplies. For intrinsically-safe applications, see the RM100 Intrinsically-Safe Fieldbus System. For installation in Zone 1 areas, see the TG300 Series Fieldbus Device Coupler.

Industry-First Advantages
Available in 4-, 8-, 10- and 20-spur models, TRUNKGUARD is the first fieldbus Device Coupler to provide fully automatic segment termination. The patented technology prevents fieldbus segment failure from under- or over-termination, a major problem in fieldbus startups. The TRUNKGUARD's auto-termination feature assures that local parts of a fieldbus segment will continue to function if remote parts of that segment are accidentally disconnected. This prevents costly downtime and hazardous situations. Other unique features include diagnostic LEDs that positively indicate power status on each fieldbus spur, spur short circuits, status of auto-termination, as well as convenient connections for a fieldbus hand-held configurator.

Short Circuit Protection
On detection of excess current on a fieldbus spur, the TG200 reacts immediately to switch spur current to a nominal trickle-level, rather than limiting the fault current to a fixed (and always higher) level as is typically done by competing units. With removal of the short, the spur is automatically reconnected to the fieldbus segment.

DIN-Rail and Complete Field-Mount Packages
TRUNKGUARD Fieldbus Device Couplers snap onto standard DIN-rail. To reduce specification and installation time, they can also be ordered in a variety of our ready-to-install field-mount, weather-proof enclosures complete with cable glands. Options include GRP (Glass Reinforced Polyester) and stainless steel enclosures with glands for armored or unarmored cable.

TG300 TRUNKGUARD™ Series 300 FOUNDATION Fieldbus™/PROFIBUS PA Device Coupler
(For Zone 1 Installations)

Trunkguard

Get Data Sheet
tg300.pdf (304K )


TRUNKGUARD Series 300 Device Couplers (TG300) deliver a fast and easy strategy to connect multiple fieldbus devices to a main fieldbus trunk in FOUNDATION fieldbus™ (H1) and PROFIBUS PA networks.

Designed for Zone 1 Areas
The TRUNKGUARD 300 Series Fieldbus Device Coupler is designed and approved for use in Zone 1 and Zone 2 with flameproof Exd devices. Each device coupler channel can be manually de-energized using a key-operated magnetic interlock. This allows individual fieldbus devices to be disconnected from the fieldbus segment without de-powering the entire segment, even in Zone 1 areas. The fieldbus device coupler's LED indicators show the current state of each channel (NORMAL, FAULT or DE-ENERGIZED).

Industry-First Advantages
Available in a 4-spur configuration, the TRUNKGUARD 300 Series is the first to provide fully automatic segment termination. The patented technology prevents fieldbus segment failure from under- or over-termination, a major problem in fieldbus startups. The TRUNKGUARD's auto-termination feature assures that local parts of a fieldbus segment will continue to function if remote parts of that segment are accidentally disconnected. This prevents costly downtime and hazardous situations. Other unique features include diagnostic LEDs that positively indicate power status on each fieldbus spur, spur short circuits, status of auto-termination, as well as convenient connections for a fieldbus hand-held configurator.

Short Circuit Protection
On detection of excess current on a spur, the TG300 reacts immediately to switch spur current to a nominal trickle-level, rather than limiting the fault current to a fixed (and always higher) level as is typically done by competing units. With removal of the short, the spur is automatically reconnected to the fieldbus segment.

DIN-Rail and Complete Field-Mount Packages
TRUNKGUARD Fieldbus Device Couplers snap onto standard DIN-rail. To reduce specification and installation time, they can also be ordered in a variety of our ready-to-install field-mount, weather-proof enclosures complete with cable glands. Options include GRP (Glass Reinforced Polyester) and stainless steel enclosures with glands for armored or unarmored cable.

FPS200 TRUNKGUARD™ High-Availability Fieldbus Power Supply
(For General Purpose and Non-Incendive Installations)

Trunkguard

Get Data Sheet
fps200.pdf (367K )


The modular and isolated FPS200 High Availability Fieldbus Power Supply provides power to FOUNDATION fieldbus™ and PROFIBUS PA fieldbus segments. It is designed for use with MooreHawke Series 200 and Series 300 Fieldbus Device Couplers, as well as any other manufacturer's non-intrinsically-safe fieldbus Device Couplers. DIN-style rail-mount FPS200 models provide power for two, four or eight fieldbus segments. Each FPS200 Carrier provides mounting positions for multiple fieldbus Segment Power Conditioners. Each Carrier also has built-in connectors for one (or two) DC supplies (18-32V). Fieldbus segment wiring can be through conventional screw-clamp terminals or via DCS-specific connectors (also provided as redundant pairs) to simplify, and minimize the amount of time required for, installation. On-board surge protection is optional.

Each fieldbus Segment Power Conditioner can be easily added (or subtracted) from the power supply's Carrier to accommodate segment changes or additions. Each Conditioner delivers up to 350mA of fully isolated and fieldbus-conditioned power per segment, fully compliant with FF831-1 and FF-registered. Individual fieldbus Segment Power Conditioners (within redundant pairs) can be removed and replaced from the Carrier under load without affecting segment operation.

General Purpose and Hazardous Area Installation
Installed in a safe area, the FPS 200 can power both general purpose devices and hazardous area devices with approved fieldbus Device Couplers. The FPS200 is also suitable for Zone2/Division 2 mounting (consult the factory for the status of hazardous area agency approvals).

SB Series SPURBARRIER™ Fieldbus Device Couplers for Intrinsically-Safe Applications (Ex e / Ex i)

SPURBARRIER

Get Data Sheet
spurbarrier.pdf (334K )


SPURBARRIER Fieldbus Device Couplers for Intrinsically-Safe Devices (Ex e / Ex i)
SPURBARRIER (SB Series) Fieldbus Device Couplers connect intrinsically-safe fieldbus devices to a non-intrinsically-safe (Ex e) trunk in FOUNDATION fieldbus H1 and PROFIBUS PA networks. They are suitable for installation in Zones 1, 2, 21, 22 (IEC) and Class 12, Division 2 (NEC) areas.

Compliant with FISCO and ENTITY specifications, SB Series Device Couplers provide up to 40mA to each of up to four intrinsically-safe spurs. Typical applications would consist of one to four units that are connected to one hazardous area trunk to support up to 16 intrinsically-safe devices on a fieldbus segment.

  • Easy implementation of intrinsically-safe fieldbus networks.
  • Protects segments from faults with auto-resetting short-circuit protection, and 1500V isolation between the trunk and spurs.
  • Flexible earthing, direct or capacitive earth connections are available.
  • LED indicators provide continuous indication of operating and fault status for each spur.
  • Power management upon start-up brings each connected fieldbus device on-line in sequence to avoid start-up overloads.

DIN-Rail and Complete Field-Mount Packages
SPURBARRIER Device Couplers snap onto standard DIN-rail. To reduce specification and installation time, they can be ordered in a variety of ready-to-install field-mount, weather-proof enclosures complete with cable glands.

RM100 ROUTE-MASTER™ Series 100 Fieldbus System
(Intrinsically-Safe Isolated Power Supply and Device Couplers)

Route-Master™

Get Data Sheet for Systems with Power Supply
rm100.pdf (525K )

Get Data Sheet for Systems without Power Supply
rm100s.pdf (327K )

Get Data Sheet for RM110
rm110.pdf (281K )


ROUTE-MASTER Series 100 Fieldbus System delivers isolated and redundant intrinsically-safe segment power and device connectivity for FOUNDATION fieldbus™ (H1) and PROFIBUS PA networks. Using a patented split-architecture design, the system delivers the highest segment current of ANY intrinsically-safe fieldbus system for the largest number of devices and/or the longest segment cable, with cable lengths of up to 1900m trunk and 120m spurs. ROUTE-MASTER enables 350mA power per fieldbus segment in intrinsically-safe applications, which permits up to 16 fieldbus devices at 500 meters (1500 feet), even in hydrogen-risk areas.

Intrinsically-Safe, Isolated Power Supply
The ROUTE-MASTER's rack-mount fieldbus power supply delivers intrinsically-safe segment power and communications to up to eight fieldbus segments to fieldbus devices mounted in a hazardous area. It provides a fully-isolated, redundantly-powered, passively-conditioned and intrinsically-safe trunk for connection into a hazardous area. No I.S. ground is required. The 350mA fieldbus segment capacity is the greatest available for any I.S. configuration, and allows normal segment design rules without undue restriction. To minimize segment voltage drop, and maximize the power available in the field, the ROUTE-MASTER can be wired to provide dual outputs from the same fieldbus segment input.

Industry-First Advantages
Available in 4-, 8-, 10- and 20-spur models, ROUTE-MASTER Fieldbus Device Couplers use the same technology as our industry-first TRUNKGUARD Fieldbus Device Couplers to provide fully automatic segment termination. The patented technology prevents fieldbus segment failure from under- or over-termination, a major problem in fieldbus startups. The ROUTE-MASTER's auto-termination feature assures that local parts of a fieldbus segment will continue to function if remote parts of that segment are accidentally disconnected. This prevents costly downtime and hazardous situations. Other unique features include diagnostic LEDs that positively indicate power status on each spur, spur short circuits, status of auto-termination, as well as convenient connections for a fieldbus hand-held configurator.

Short Circuit Protection
On detection of excess current on a spur, the ROUTE-MASTER reacts immediately to switch spur current to a nominal trickle-level, rather than limiting the fault current to a fixed (and always higher) level as is typically done by competing units. With removal of the short, the spur is automatically reconnected to the segment.

DIN-Rail and Complete Field-Mount Packages
ROUTE-MASTER Fieldbus Device Couplers snap onto standard DIN-rail. To reduce specification and installation time, they can also be ordered in a variety of our ready-to-install field-mount, weather-proof enclosures complete with cable glands. Options include GRP (Glass Reinforced Polyester) and stainless steel enclosures with glands for armored or unarmored cable.